Readme for Firmware Firmware file: 199925213400-29_3.7.0.sqrfw Applies to Siqura models: TrafficPTZ Ultimo UP36 Version information: Firmware version 3.7.0 Revisions: 3.7.0 (Date 2021-03-18) FIX: Web app: Move the Highlight mask from exposure to Enhancement tab FIX: Sony 30x zoom block Manual Focus issue FIX: Firmware update fails under load (and reverts to factory image) FIX: UP36: Increase the Pan, Tilt and zoom speed when the camera is zoomed in FIX: CPU load parameter get stuck at 100% FIX: UP36: Fix incorrect Focus normalization for zoom block FIX: The shutter mode/setting is lost after reboot. XCU with new 10x zoom block CHG: Buildserver should use FUG_rules from BitBucket CHG: FIX the version number not updating on incremental build 3.6.1 (Date 2021-01-04) FIX: Duplicate transmitter ports on RTP/UDP 3.5.2 (Date 2020-10-13) FIX: Multiple authentication requests after enabling user authentication. FIX: Do not feed the TDL with frames when framerate is unknown (0 fps divide by zero in TDL). ADD: Show an invalid PID configuration is set in OSD. CHG: Version numbers are generated through `git describe` instead of `0.0.0` for better tracability. CHG: Web app shows a loading indicator when loading/authenticating. CHG: Web app correctly logo padding. 3.5.0 (Date 2020-06-03) ADD: Potential vulnerability for ClickJacking ADD: support for new 36x zoom block CHG: Add possibility to disable SNMP CHG: Add 24-bits support for audio level meter CHG: Add true RMS mode for audio level meter CHG: NTCIP: globalTime setter/getter CHG: Heater can't be turned on when powered by POE Improvement FIX: VCA: Unusable color palettes in Hotspot Monitor FIX: VCA: Palettes are not shown correctly FIX: Warped image when streaming QCIF or QVGA with 5:4 aspect ratio FIX: Add compass function to TPU/BC840v2/UP30/UP36 FIX: PID does not work correctly on TAU2-cores with 336 resolution FIX: Race in calling GenetecParameterManager::CheckDataBaseContent FIX: Combine 2 ADCs on xcu 3.4.0 (Date 2020-02-06) ADD: PID: Extend VCA event processing so all VCA-events are translated to external Siqura events (SPI and Onvif) ADD: Add Genetec discovery protocol ADD: Add MAPI parameters to the HotSpot feauture to read-out the measured Temperature in a ROI ADD: TPU (UPxx/BC840v2) Add an extention to the TPU driver for D/N mode and zoom ration ADD: Software support for updated 4x and 10x (M1) zoom blocks in XCU cameras (ready for frontend-testing) ADD: Software support for new zoom blocks in XCU cameras (ready for frontend-testing) ADD: Show out of date message web browser FIX: Webapp: "Image Settings" page and "Thermal Settings" page only visible after a page-reload after logging in FIX: Sometimes corrupted initial settingsfile for 802.1x cause a lot of logging FIX: 4x zoom actual zoom position lost after factory default FIX: Logfile full with 'LLDP allocated power: 20700mW', 'LLDP allocated power: 0mW', etc... FIX: Zoom position changed after firmware upgrade to 3.1.3 or above FIX: Camera focus and zoom position slightly repositioned after reboot 3.3.4 (Date 2019-10-02) FIX: SVW picture freezes when second display connects to same camera FIX: Bitrate can be set to extremely high values by setting "Maximum bit rate" to 0 FIX: ONVIF SetVideoEncoderConfiguration gives error message 3.3.1 (Date 2019-08-09) FIX: Camera unreachable when setting empty Admin password FIX: Password field cleared in browser authentication window each 5 seconds after changing Admin password 3.3.0 (Date 2019-08-05) ADD: ONVIF: possibility to set FrameRateLimit to any value between 1..25/30 fps ADD: Webapp: Telnet- and FTP enable/disable on webapp and global warning when Telnet and FTP enabled ADD: new optional queries "?transportmode=unicast" or "?transportmode=multicast" options to the RTSP-URI ADD: Extra logging when firmware upgrade is started ADD: Add current IP as "alternate name" in certificate CHG: HTTPS: change self-signed certificate to infinite (100 years) FIX: NTP client rejects stratum level 16 servers FIX: HTTPS: new certificate each time the camera is rebooted FIX: Webapp: privacy masks can not properly be edited anymore FIX: Settings file lost on brief power interruptions FIX: ONVIF: reboot when trying to go to, delete or update an existing PTZ-preset FIX: MulticastTransmitterAlwaysOn does not always work FIX: SPI API: PTZ GotoAbsoluteZoomPosition does not accept negative pan values 3.2.0 (Date 2019-04-18) ADD: Cyber Security Enhancements CHG: Security: block access on X wrong credentials ADD: Notification when NTP server is offline ADD: Logging when ethernet network link disconnects CHG: addition of the Genetec SET_PARAMETER-KeyFrameRequestMethod CHG: Confusing SD-card log message after firmware upgrade FIX: ONVIF sets same multicast address+port for Direct streaming and RTSP FIX: NTCIP: Iris/Focus control not correctly implemented 3.1.0 (Date 2019-01-08) FIX: SPI: SDCardStatus custom event is not triggered FIX: NAS traffic shaping affects RTSP-stream FIX: ONVIF: Pass the conformance test on Testtool v18.06 SR1 FIX: Aux1..Aux8 control via ONVIF FIX: ONVIF: GetVideoEncoderConfigurationOptions returns corrupt ResolutionsAvailable-list FIX: Card insertions/removals are not logged FIX: Umlauts in camera name not displayed in OSD FIX: Crash upon startup when SNMP Authentication trap is enabled FIX: Webapp: Driver Management and Data page visible on TrafficPTZ FIX: Webapp: camera ID should not be selectable on TrafficPTZ ADD: Warning when user sets authentication for viewing when no users are defined 3.1.0 Date 2019-01-08, branch "release_3.1.x" Fixed: * [FW-185] - SPI: SDCardStatus custom event is not triggered * [FW-476] - NAS traffic shaping affects RTSP-stream * [FW-576] - ONVIF: Pass the conformance test on Testtool v18.06 SR1 * [FW-588] - Aux1..Aux8 control via ONVIF * [FW-607] - ONVIF: GetVideoEncoderConfigurationOptions returns corrupt ResolutionsAvailable-list * [FW-621] - Card insertions/removals are not logged * [FW-674] - Umlauts in camera name not displayed in OSD (Mantis #1583) * [FW-675] - Crash upon startup when SNMP Authentication trap is enabled * [FW-678] - Webapp: Driver Management and Data page visible on TrafficPTZ * [FW-679] - Webapp: camera ID should not be selectable on TrafficPTZ Added: * [FW-605] - Warning when user sets authentication for viewing when no users are defined 3.0.0 (Date 2018-11-15) FIX issue: firmware upgrade can brick device IMPORTANT NOTICE: Due to the nature of this fix, you CANNOT DOWNGRADE back to v2.x. If, for some reason, a downgrade to a specific version is needed, please contact your Siqura support team. The major version number is increased to indicate this downgrade limitation. This v3.0.0 release is based on the last v2.x release (v2.21.0). Beside this important single fix, there are no changes as compared to the last v2.x release. 2.21.0 (Date 2018-10-18) (Unreleased, contains dedicated changes for AID-products only) 2.20.0 (Date 2018-10-01, based on 2.18.0) FIX: BC840v2 + TrafficPTZ: Autofocus not activated when PTZ, Abs. Pos. or Preset Pos. is done via ONVIF FIX: Activating usermanagement gives an incomplete webgui until refreshed FIX: Webapp is more or less useless when user management is activated FIX: PTZ-camera in manual focus mode does not always jump back to auto-focus when panning/tilting on the webapp FIX: VCA: blob timestamps are incorrect FIX: PID: Blob trigger point bottom-center has unexpected behavior FIX: Reset Password doesn´t work FIX: Webapp browser autocomplete adding new user making it unusable. FIX: NAS: ClipManager-instances are not cleaned up after changing storage configuration FIX: NAS: support for large NAS-devices (> 4 TB) FIX: RTSP: Missing CSeq in 401 Unauthorized response CHG: Added many features to ONVIF recording control, search and replay FIX: No bidirectional PTZ-drivers available in s60e-v2 product 2.18.5.int.20181023 (Date 2018-10-23, based on 2.18.0) FIX: ONVIF GetVideoEncoderConfigurationOptions returns corrupt ResolutionsAvailable-list 2.18.0 (Date 2018-08-09) FIX: Bug in image.cgi: crash when only width is specified ADD: NAS-recording CHG: 24-bit audio: Make 24-bit audio profile the default profile when 24-bit is enabled (TTP #1997) CHG: Logging improvement to be able to see which 'TcpConSrvCon'-task is 'hanging' 2.16.1 (Date 2018-06-08) FIX: Recording button on live view page does not work 2.16.0 (Date 2018-06-31) FIX: NTCIP systemCameraFeatureStatus response is not correct 2.15.0 (Date 2018-05-15) ADD: support for additional front ends CHG: added security provision 2.13.0 (Date 2018-03-16) ADD: PTZ Privacy Masks ADD: Actual preset returned in Data-1.Ptz-1.ActualPreset parameter FIX: crash when Edge Recording API queries were made for a not existing input FIX: ONVIF http:///topicns.xml could not be retrieved FIX: NTCIP relative pan and tilt do not work (TrafficPTZ) FIX: SPI PTZ group sometimes Ptz, sometimes PTZ; must always be PTZ FIX: Long term bitrate can be enabled after upgrade while not visible on webpage anymore 2.11.0 (Date 2018-01-12) FIX: settings lost after downgrade from 2.9.0 FIX: Separate color palette for isotherm mode (products with thermal sensor only) FIX: Not possible to add a node with MSIE11 FIX: movement artifacts visible on S-60 D-MC when using H.264 S-60 D encoding profile FIX: SPI always reported support for PTZ-patterns (also when not supported) ADD: 24-bit audio possibility (on selected product) ADD: PTZ-drivers for COHU (codecs only) ADD: Dedicated RTSP URI for video without audio (e.g. rtsp:///VideoOnly-1.Encoder-1) ADD: 16 Privacy Masks for TCU and MCU 2.6.1 (Date 2017-09-18) FIX: TTP1923 ONVIF absolute pan/tilt readout was incorrect FIX: TTP1939 Misconfigured trafficshaping with 2 multicast streams to the same destination port 2.6.0 (Date 2017-07-21) CHG: Increased the TCP-streaming buffer size CHG: OpenSSL upgraded to 1.0.2l 2.4.1 (Date 2017-06-29) FIX: Absolute PTZ position readout and set using Genetec Security Center 2.4.0 (Date 2017-06-07) CHG: Special SPI preset- and aux- commands to control washer, wiper and IR-lamp CHG: Wiper timeout increased from 5 seconds to 10 seconds CHG: ONVIF generic coordinate space tilt changed to -40..+90 degrees 2.1.1 (Date 2017-03-06) CHG: Embedded help is updated to latest version. CHG: Pressing enter in direct streaming page no longer resuls in SDP download. FIX: disabling auto image enhancement resulted in very dark image. FIX: no longer an igmp join is send when onvif discovery is disabled. FIX: german translations are updated. FIX: favicon.ico is updated to rebrand. FIX: translation error when no privacy mask was created. FIX: RTSP multicast address could not be changed in IE11. FIX: french translations are updated. FIX: privacy masks could not be edited. FIX: ConnectionLoss event on SPI not fired for Connection monitor. 2.1.0 (Date 2017-02-01) CHG: Various small web app changes/fixes CHG: Various SPI additions CHG: Added aspect ratio setting CHG: Added PTZ enable checkbox (disable/enable PTZ on the web page, ONVIF, SPI and MAPI) CHG: Edge recording is now file based on SD-card (SD card need to be formatted after upgrade) CHG: Edge recording can be triggered with all event types (not just connection monitor) CHG: Edge recording continuous recording mode possibility CHG: ONVIF profile G (recording) partially implemented (not fully compliant) CHG: Various small changes/fixes for NTCP 1.7.5 (Date 2016-11-15) CHG: Added support for H.264 BP on Ionodes ION-R100 decoder Fixed: FIX: Actual bit rate slightly higher than set bit rate FIX: TrafficPTZ does not have SNMP and NTCIP FIX: Updated lib UPnP to 1.6.20. This resolves Portable SDK for UPnP Devices (libupnp) < 1.6.18. Multiple Stack-based Buffer Overflows RCE (CVE-2012-5958, CVE-2012-5959, CVE-2012-5960, CVE-2012-5961, CVE-2012-5962, CVE-2012-5963, CVE-2012-5964, CVE-2012-5965) FIX: 4-Channel devices reboot after 20 hours when less than 2 video sources connected 1.7.4 (Date 2016-09-21) FIX: Instability issue with H.264 and MJPEG encoders (M3-platform) 1.7.3 (Date 2016-07-28) FIX: TTP 1822 Real time clock is not set when using NTP FIX: Revert of fixed Typo in ONVIF response: DefaultAbsolutePantTiltPositionSpace (this typo was actually made in the ONVIF WSDL specification so should not be corrected) 1.7.2 (Date 2016-06-01) CHG: Updated warnings when using an old version of a browser (only the last two versions of each browser are supported) CHG: Added extra snapshot URL for Siemens/ASFiNAG: http:///cameras/.jpg CHG: Added an extra confirmation dialog when resetting to factory defaults CHG: Added encoder bitrates as measurement to be used on Overlays (OSD) CHG: Wiper automatically switches off after 5 seconds CHG: Presets can be renamed on live view page CHG: More accurate pan/tilt control on live view page by using the entire image for the PTZ-joystick CHG: Firmware support for front-end mounted flipped on the assembly (for better thermoregulation in the camera) FIX: Zoom/Focus/Iris sliders on live stream page did not automatically center when released in Firefox FIX: Day/night transition IR cut filter threshold did not function properly FIX: Resolutions "1920x1080" and "1280x720" added to encoder resolution list 1.7.1 (Date 2016-05-11) FIX: Product not starting up (pthread_timed_mutex() crashes on console) with illegal date in hardware clock 1.7.0 (Date 2016-05-04) Intial version for the TrafficPTZ Ultimo